GearUP AC Distribution Box 8 Way in Bangladesh

The GearUP AC Distribution Box – 8 Way (1 in 1 out) is a heavy-duty power distribution solution designed for AC 400V systems. With a 63A capacity and durable build, it safely distributes electricity to multiple circuits while protecting against overloads, short circuits, surges, and leakage currents.
Equipped with premium Tomzn components—including DC fuse holders, surge protectors, miniature circuit breakers, and RCCB/RCBO units this box ensures reliable, organized, and secure power management for homes, businesses, and solar installations
Features
- High Capacity: Supports up to 63A rated current for stable and reliable power distribution.
- Durable Build: Made with high-quality materials for long-lasting performance.
- 8-Way Configuration: Distributes power to multiple circuits from a single input.
- Wide Voltage Support: Designed for AC 400V systems to suit various electrical setups.
- Safe & Efficient: Organizes and secures AC power distribution for safety and ease of use.
Specifications
- Brand: GearUP
- Rated Current: 63A
- Voltage: AC 400V
- Configuration: 8 Way (1 in 1 out)
- Dimensions: 20.5 cm × 20 cm
Internal Components
1. TOQ1-32K (Tomzn)
- Type: Isolator Switch (Disconnect Switch)
- Voltage: 500V AC
- Current Rating: 32A
- Poles: 2 Pole
- Function: Disconnects the circuit from the load.
2. TOQ1-32 (Tomzn)
- Type: Isolator Switch
- Voltage: 500V AC
- Current Rating: 32A
- Poles: 2 Pole
- Function: Isolates or turns off a circuit.
3. TOV1-C (Tomzn) – Surge Protective Device (SPD)
- Voltage Protection Level: 385V
- Imax (Max Discharge Current): 40kA
- In (Nominal Discharge Current): 20kA
- Type: Type 2 SPD (IEC61643-1 standard)
- Quantity: 2 units
4. TOB1-63H C63 (Tomzn)
- Type: MCB (Miniature Circuit Breaker)
- Current Rating: 63A
- Trip Curve: C Curve
- Voltage: 400/230V AC
- Poles: 1 Pole
- Function: Protects against overload and short circuit.
5. TOB1L-63H C63 (Tomzn)
- Type: RCCB/RCBO (Residual Current Circuit Breaker with Overcurrent Protection)
- Current Rating: 63A
- Trip Curve: C Curve
- Voltage: 400/230V AC
- Sensitivity: 30mA (typical)
- Function: Combines overload/short-circuit protection with leakage current detection.
6. Additional Blue Switch MCBs
- Current Rating: 6A–32A (approx., based on photo)
- Function: Protects individual circuits from overload or short circuit.
Component Details
১. DC Fuse Holder (বাম পাশের ২টি)
- কাজ: অতিরিক্ত কারেন্ট বা শর্ট সার্কিট হলে ফিউজ গলে লোড বিচ্ছিন্ন করে।
- ব্যবহার: মূলত সোলার PV সিস্টেম বা DC সার্কিটে।
- ফিচার:
- রেটেড ভোল্টেজ: 500V/850V DC
- সাইজ: 10×38 mm ফিউজের জন্য
- নোট: “Do not open under load”
২. TOMZN TOV1-C – Surge Protective Device (পরের ২টি)
- কাজ: বজ্রপাত বা ভোল্টেজ স্পাইক থেকে সিস্টেম সুরক্ষা।
- ফিচার:
- Uc: 385V~
- Imax: 40kA
- In: 20kA
- প্রতিস্থাপনযোগ্য কার্টিজ (Red/Replace ইন্ডিকেটর)
৩. TOMZN TOB1-63H C63 – Miniature Circuit Breaker (পরের ১টি)
- কাজ: ওভারলোড বা শর্ট সার্কিটে স্বয়ংক্রিয় বিদ্যুৎ বিচ্ছিন্ন।
- ফিচার:
- রেটেড কারেন্ট: 63A
- রেটেড ভোল্টেজ: 400V~
- ব্রেকিং ক্যাপাসিটি: 6000A
- টাইপ: C Curve
৪. TOMZN TOB1L-63H C63 – RCCB/RCBO (নীল সুইচ সহ ২টি)
- কাজ: ওভারলোড ও শর্ট সার্কিট সুরক্ষা + লিকেজ কারেন্ট ডিটেকশন।
- ফিচার:
- রেটেড কারেন্ট: 63A
- লিকেজ ট্রিপ: 30mA
- ভোল্টেজ: 230/400V~
- টেস্ট বোতাম সংযুক্ত
সারাংশে মোট ডিভাইস:
- DC Fuse Holder – 2টি
- Surge Protective Device (SPD) – 2টি
- Miniature Circuit Breaker (MCB) – 1টি
- RCCB/RCBO – 2টি